la sottomissione degli articoli a Biochimica Clinica (e il successivo processo editoriale) avverrà obbligatoriamente attraverso la piattaforma SCHOLAR ONE.
Qui di seguito il link per il collegamento alla piattaforma.
La segreteria di redazione può essere contattata per ogni necessità al 335 6159776 o all’indirizzo biochimica.clinica@sibioc.it
Member area login
You don't have or don't remember the password! Click Here
Editor-in-chief
Maria Stella Graziani
Deputy Director
Martina Zaninotto
Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali
EIC Assistant
Francesco Busardò
International Advisory Board
Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada
Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano
Responsible Editor
Giuseppe Agosta
Editorial Secretary
Chiara Riva
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it
--------------------
ISSN print: 0393 – 0564
ISSN digital: 0392- 7091
BC: Articoli scritti da A. Sensi
Varianti rare dell’emoglobina: la nostra esperienza con gli analizzatori Sysmex di ematologia
Rare hemoglobin variants: our experience with Sysmex hematology analyzers
<p>The consolidation of laboratory activities optimizes resources and improves the expertise of the staff that encounters more frequently rare and exceptional cases. In the recent months, the Romagna Greater Area Laboratory, which provides a diagnostic service for over a million inhabitants in North Italy, detected an unusual instrumental alarm in a few routine blood counts. Further investigations demonstrated the presence in the samples of hemoglobin (Hb) variants, characterized with subsequent molecular analysis as Hb Leiden and Hb G-Ferrara. These Hb variants reduce the fluorescence signal hampering the differential leukocyte count carried out by the Sysmex XE2100 hematology analyzer. In all the investigated cases, irregular contracted red blood cells (RBC) and target RBC were present. HPLC analysis of the two Hb variants shows Hb Leiden and Hb G-Ferrara peaks at 4.28 min and 3.23 min of elution time, respectively. It is clinically important to identify carriers of these variants in specific clinical setting, since heterozygotes for these Hb variants are asymptomatic, but complications could be induced by drug therapies, viral infection or heterozygosity for b-thalassemia or other Hb variants. Our findings demonstrate the importance to investigate samples with low fluorescence when assayed using Sysmex analyzers. Finally, the reported cases confirm the effectiveness of tight integration between huge routine workload and specialized competence for the detection of unusual clinical conditions.</p>
Gentile utente, le ricordiamo che l'accesso alla rivista è riservato ai soci SIBioC in regola con la quota associativa.
Per accedere alla pagina richiesta è necessario inserire il suo nome utente e la password nella sezione "AREA SOCI".
A disposizione per ulteriori informazioni.
La Segreteria SIBioC
Dear User, please note that access to the Journal is for SIBioC members who have renewed their membership fee.
To access the requested page you need to enter username and password in "Area Soci".
At your disposal for further information.
SIBioC Secretariat