You don't have or don't remember the password! Click Here
Editor-in-chief
Maria Stella Graziani
Deputy Director
Martina Zaninotto
Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali
EIC Assistant
Francesco Busardò
International Advisory Board
Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada
Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano
Responsible Editor
Giuseppe Agosta
Editorial Secretary
Chiara Riva
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it
--------------------
ISSN print: 0393 – 0564
ISSN digital: 0392- 7091
BC: Articoli scritti da M. Orfano
Valutazione degli anticorpi anti SARS-COV-2 nell’ambito di un progetto di costituzione di una banca di plasma iperimmune
SARS-COV-2 antibodies in patients candidates as donors of immune plasma
<p>Background: in this study SARS-CoV-2 serology was investigated, using three different methods, in a cohort of convalescent patients from SARS-CoV-2 infection, recruited for the establishment of a hyperimmune plasma bank.<br />Methods: SARS-CoV-2 serology was investigated in 326 subjects using three commercial methods: MAGLUMI (MAG) 2019-nCoV IgM CLIA, MAGLUMI 2019-nCoV IgG CLIA and DiaSorin (SOR) LIAISON SARS-CoV-2 S1/S2 IgG. Moreover, 143 subjects were tested using a plaque reduction micro neutralization assay.<br />Results: MAG IgG test and SOR IgG test showed a good agreement (Cohen's K index = 0.65, CI 95% 0.55 – 0.78). Considering SOR IgG test versus micro neutralization test, the observed cut-off values were: 85 AU/mL for a neutralizing titer of 1/80; 108 AU/mL for 1/160 titer and 144 AU/mL for 1/320 titer. Considering MAG IgG test versus micro neutralization test, the observed cut-off values were: 4 AU/mL for a neutralizing titer of 1/80, 5 AU/mL for 1/160 titer and 7 AU/mL for 1/320 titer.<br />Conclusions: in our experience, the MAG and SOR tests showed good agreement in identifying subjects with IgG antibodies to SARS-CoV-2. Obtained results confirmed a good correlation between the antibody concentration detected by the SOR IgG and the neutralizing titer determined by the plaque reduction test.</p>
Gentile utente, le ricordiamo che l'accesso alla rivista è riservato ai soci SIBioC in regola con la quota associativa.
Per accedere alla pagina richiesta è necessario inserire il suo nome utente e la password nella sezione "AREA SOCI".
A disposizione per ulteriori informazioni.
La Segreteria SIBioC
Dear User, please note that access to the Journal is for SIBioC members who have renewed their membership fee.
To access the requested page you need to enter username and password in "Area Soci".
At your disposal for further information.
SIBioC Secretariat