You don't have or don't remember the password! Click Here
Editor-in-chief
Maria Stella Graziani
Deputy Director
Martina Zaninotto
Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali
EIC Assistant
Francesco Busardò
International Advisory Board
Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada
Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano
Responsible Editor
Giuseppe Agosta
Editorial Secretary
Chiara Riva
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it
--------------------
ISSN print: 0393 – 0564
ISSN digital: 0392- 7091
BC: Articoli scritti da P. Iandolo
La stima dell'incertezza delle misure nel laboratorio clinico
Measurement uncertainty calculation in clinical laboratories
<p>The result of a measurement is only an estimate of the value of the measurand and it is complete only when accompanied by a statement of the measurement uncertainty. The ISO 15189 standard requires that “the laboratory shall determine measurement uncertainty for each measurement procedure”. The approach to calculate the measurement uncertainty proposed by the “Guide to the expression of uncertainty in measurement” (GUM) requires the quantification of every source of variability to sum them up for the final calculation (“bottom-up” approach). To overcome inherent difficulties in the systematic application of this approach in a clinical laboratory, a "top-down" approach is proposed, through the calculation of measurement uncertainty from already existing data of IQC. The proposed approach is checked by applying it to the IQC data for serum glucose and creatinine measurements collected from 19 clinical laboratories. Different approaches to cope with the issue of the estimate of systematic error (bias) are proposed, based either on value-assigned trueness control/reference materials, on the mean value of the employed material defined by the laboratory at the start of the IQC program or on the peer group mean of an interlaboratory program material. The availability of a standardized way to estimate the measurement uncertainty provides a tool to evaluate the analytical quality of results and it allows comparison of the quality of results made available by different laboratories.</p>
Gentile utente, le ricordiamo che l'accesso alla rivista è riservato ai soci SIBioC in regola con la quota associativa.
Per accedere alla pagina richiesta è necessario inserire il suo nome utente e la password nella sezione "AREA SOCI".
A disposizione per ulteriori informazioni.
La Segreteria SIBioC
Dear User, please note that access to the Journal is for SIBioC members who have renewed their membership fee.
To access the requested page you need to enter username and password in "Area Soci".
At your disposal for further information.
SIBioC Secretariat