Member area login
You don't have or don't remember the password!
Click Here
Editor-in-chief
Maria Stella Graziani

Deputy Director
Martina Zaninotto

Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali

EIC Assistant
Francesco Busardò

International Advisory Board Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada


Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano

Responsible Editor
Giuseppe Agosta

Editorial Secretary
Chiara Riva
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it

--------------------

ISSN print: 0393 – 0564
ISSN digital: 0392- 7091



BC: Articoli scritti da O. Costanza

Interferenza analitica sul conteggio dei leucociti
Analytical interference on leucocyte count
<p>Chronic lymphoproliferative disorders typically affect elderly patients with a median age at the diagnosis of 71 years. These disorders include a number of conditions characterized by an abnormal proliferation of lymphocytes towards a monoclonal lymphocytosis. The case of an 83-year-old man affected by chronic lymphocytic leukemia is presented; the peripheral blood cells count, performed on the analyzer Sysmex XN-20, showed significant differences between the white nucleated red (WNR) and white differentiation (WDF) channels that did not allow the differential counting of leukocytes. On the opposite, the reflex analysis channel white progenitor cell (WPC), returned the correct white blood cell count. Actually, when the peripheral blood sample was diluted (1:5) and resubmitted to analysis, leukocytes count resulting from WNR and WDF analysis channels corresponded to that obtained in the reflex WPC analysis channel on the undiluted sample. To verify if the instrumental anomaly found in the cell counting could be associated to an elevated plasma concentrations of immunoglobulins, a serum protein electrophoresis was performed, showing the presence of four monoclonal components. These data demonstrate that the WPC channel is an important tool for the clinical laboratory, since it is able to give a correct result even when interferents are present.</p>
Biochimica Clinica ; 45(2) e11-e14
Casi Clinici - Case Report